Down from top and up from bottom of ledger and staggered up down.
Ledger bolts roof.
Remove the ledger and drill bolt holes where the bolt tips have left marks.
For a 2x8 ledger the bolt must be at least 5 1 2 inches from the top of the ledger 4 1 2 inches is the minimum when the ledger attaches to a 2x8 band joist.
Although more work it is absolutely a bullet proof solution.
Plus you need to double fasteners at ledger butts and ends.
Either expansion bolts or epoxy can be used in this scenario.
X 9 in.
The most common method is to install lag bolts with washers or carriage bolts with washers.
If metal flashing is used holes must be drilled through the metal prior to drilling out the concrete.
It only weighs 100 pounds it is a ledger board a front plate and eight 2x4 rafters sitting on two 4x4 posts.
The table includes in.
Lag screws and machine bolts.
Bolts and screws must be located 2 in.
Never counter sink bolts.
For this reason structural screw manufacturers that market fasteners specifically designed for ledger connections provide engineered fastener patterns and load tables and these are the ones you must use.
For a really durable job consider applying 30 felt paper or metal flashing between the ledger and the concrete.
Flashing a patio roof ledger.
Push or hammer the ledger back onto the bolts recheck for level making any needed adjustments add washers and nuts and then tighten the bolts.
The bottom bolt must be a minimum distance from the top of the ledger.
I want to attach the ledger board directly into the hardiboard siding of the garage with lag screws using washers as spacers for drainage between the ledger and the siding.
Table of bolt spacing for deck ledger spaced away from the building.
You will usually need the length of the bolt to be at least 4 6 to penetrate through the 2x ledger board the house sheathing and into the solid house rim.
House rim joist must be minimum of 2x sawn lumber or 1 in.
The first bolt goes in from the end at least 2 inches and not more than five.
Even if the screw were magically invincible more structural screws would be required than lag screws to provide the same load bearing capacity.
Spacing for bolts and lags used to connect the deck ledger to the building are shown in the table at above right ledger bolted directly to the building and at in the figure at left for deck ledgers that are spaced away from the building.
Standard galvanized lags and carriage bolts.
That distance varies depending on the ledger size.
The bolt pattern must be clearly thought out 5 06 considering a 2x10 ledger and a 2x10 band joist as an example let s start at the beginning.
The ledger basically hangs on the top bolts but sits atop the bottom bolts so more space is allowwed.